Fluke 773 Milliamp Process Clamp Meter
$64.68
$87.96
The 773 is ideal for troubleshooting transmitters, valves, and programmable logic controllers (PLCs) found in process plants. The 773 allows you to connect to a mA loop in a traditional series workflow to measure, source, or simulate a control system. And it measures up to 99.0 mA non-contact, including 10 to 50 mA signals in older control systems. The 773 also sources and measures DC voltage, so it can be used to troubleshoot voltage input and output devices that accept a 1-5 V or 0 to 10 V signal. You can detach the clamp section of the meter and use it as a remote jaw, connected to the main body by an extension cable to make it easier to take measurements in tight spaces. Work smarter with the 778 mA Clamp Meter An integrated measurement spotlight allows you to illuminate hard to see wires in dark enclosures while a dual backlit display can show mA measurement and percent of 4 to 20 mA span simultaneously. Use the Hold function to capture measurements on-screen for verification and recording purposes. Plus, automatic power-off features save battery life so you can work longer without changing the batteries. Advanced loop troubleshooting With the unique mA scale feature users can measure a mA signal without breaking the loop and output that signal to another device to record the measurements. The 773 also includes simultaneous mA in-circuit measurement with 24 V loop power for powering and testing transmitter. You can also apply a mA input signal to a device and measure its 4-20 mA output on devices such as valves or mA isolators. Offers mA or voltage output linear ramp or 25% step output. Specifications: Fluke 773 Milliamp Process Clamp Meter Specifications Diameter of measurable conductor 0.177″ or 4.5 mm max Operating temperature -10 to 50ºC Storage temperature -25 to 60ºC Operating humidity < 90% @ <30ºC, < 75% @ 30 to 55ºC Operating altitude 0 to 2000 m IP rating IP 40 Size 44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in) Weight 410 g, (14.4 oz) Vibration Random 2 g, 5 to 500 Hz Shock 1 meter drop test (except the jaw) EMI/RFI Meets EN61326-1 For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m. Temperature coefficient 0.01% ºC(< 18ºC or > 28ºC) Power, battery life (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms Warranty Three years for electronicsOne year for cable and clamp assembly Functional Specifications mA measurement(measured by clamp) Resolution / range 0 to 20.99 mA Accuracy 0.2% 5 counts Resolution / range 21.0mA to 100.0 mA Accuracy 1% 5 counts mA measurement (measured in series with test jacks) Resolution / range 0 to 24.00 mA Accuracy 0.2% 2 counts mA source (maximum mA drive: 24 mA into 1,000 ohms) Resolution / range 0 to 24.00 mA Accuracy 0.2% 2 counts mA simulate (maximum voltage 50 V dc) Resolution / range 0 to 24.00 mA Accuracy 0.2% 2 counts Voltage source (2 mA maximum drive current) Resolution / range 0 to 10.00 V DC Accuracy 0.2% 2 counts Voltage measure Resolution / range 0 to 30.00 V DC Accuracy 0.2% 2 counts
Process & Industrial